Posting on behalf of Stephanie O’Brien, PGY1 Resident:
Hello,
For my research project this year I identified a liquid medication dosing error in our neonatal intensive care unit that is not detected by our electronic health record. Physicians enter a mg/kg dose into the EHR which automatically calculates a mL dose based on the patient's weight and the drug concentration. The EHR does NOT alert the physician if the mL dose is unmeasurable so we are seeing several instances where patients are being prescribed unmeasurable doses.